How To Make Gel Pads Sticky Again
Roots of Being is reader supported. When you buy through our links, we may get a commission.
The adhesive pads are critically of import parts of your TENS device. These pads are responsible for making sure that the device is in contact with your torso through the session. In social club for your TENS/EMS units to work properly, it has to be attached correctly.
If the pads or electrodes autumn off, the electrical energy produced won't reach your torso efficiently, and the system won't piece of work.
This is a common issue with TENS units and can be fixed in a variety of ways. In this commodity, we'll discuss How to Make TENS Unit Pads Glutinous Again. We'll also go over how to foreclose them from losing their stickiness going forward. Only to start, let's kickoff become over why these electrodes or pads lose their stickiness.
What Causes TENS Unit of measurement Pads To Lose Their Stickiness
TENS unit pads are reusable as long every bit they nevertheless stick to your skin. The trouble starts when they begin to lose their stickiness. There are unlike reasons why this happens. The primary reason is because of the dirt, debris, and oil on the skin.
When the pads are used on skin that hasn't been cleaned, it is possible to transfer the oils, dirt, and debris. Even the dead skin cells tin can attach to the adhesive, which the pad from sticking on other surfaces again.
If you haven't used your TENS unit of measurement for a long time and it has been in storage, it is possible that the gel pads have dried up. Apart from the gel pads themselves, information technology is as well possible that the adhesive dries up over time and equally the pads are used.
How to Make TENS Unit Pads Sticky Again
Now that we know that the causes of losing the stickiness, nosotros'll exist amend able to resolve the trouble.
For dirty TENS unit pads, all that needs to exist done is to clean the pad(south). For those that have dried up, y'all but have to hydrate them. And if all else fails, then that's the time to consider buying replacement pads so y'all can still utilise your TENS Unit.
How To Make clean TENS Pads
Before you restore the stickiness on your used TENS pads, you'll need to make clean them off and get them in pristine shape for re-use. The best manner to make clean your TENS pad is with a microfiber textile, similar to the ane shown below.
Here'due south a step-by-stride guide to cleaning off your TENS pads.
- Set the materials you lot need for cleaning. This will unremarkably consist of h2o and a damp cloth. Whatsoever cloth volition do just it would be all-time to use Microfiber Glass Cleaning Cloths, which are lint-gratuitous. This will forestall fiber from your cleaning fabric to stick on the pads.
- Disconnect the electrode pads from your TENS unit. Earlier cleaning make sure the TENS unit device is off and the pads are asunder from the unit. This is for safety purposes and it is also makes cleaning easier because your range of motion isn't limited by the wires.
- Wipe the pads with the clammy cloth. Wipe off all the dirt and droppings on the gel pads with your damp fabric. You don't have to use a lot of force to exercise information technology. Yous should do them gently then you don't damage the pads. The stickiness may not necessarily exist observed while the pads are still a bit moisture. Merely let it dry out upwardly a bit before trying to stick it again to your trunk.
- Use a toothbrush (no, not the one you use!) to betrayal the viscous surface. After wiping off with the damp material, you may also use a toothbrush to help get the surface pasty again. The toothbrush gently exposes the mucilaginous surface of the pads so it tin can efficiently stick to the peel once once again.
How To Rehydrate TENS Electrode Pads
No products constitute.
If the gel pads are likewise dry, they might demand to be rehydrated to regain the tackiness or stickiness they once had.
Don't brand the error of placing the gel pads under running h2o or submerging them. These volition oversaturate the gel. The all-time way to rehydrate the gel pads with water is to employ a dropper and add drops of water gradually.
Gels and Electrolyte Sprays like this Parker Signa Spray can be used to ameliorate electrical conductivity. However, you tin also attempt using them to hydrate the gel pads. Using these tin help lengthen the life of your electrode pads.
TENS Unit Electrode Pad Replacement
If yous tried cleaning the electrode pads and rehydrating them, it is still possible that they won't get their stickiness back. The pads are designed to exist reusable and to final long but they also have their limits. When yours accept reached them, information technology would be best to find replacements that are compatible with your unit.
At that place are universal unit electrode replacement pads like the AUVON Tens Unit Pads, shown above. These have a standard 2mm connector. Just brand sure your TENS unit device uses the standard 2mm connectors.
If you lot are unsure about the connections of your unit of measurement, check your transmission or purchase replacement pads specifically produced for that device.
How To Preclude Losing Stickiness From Your Electrode Pads
Instead of finding a solution to the stickiness trouble, the best solution is to prevent it from happening. You can prevent your pads from losing their stickiness past regularly cleaning both the pads and the areas on your trunk you'll be placing the pads.
You can use alcohol and a cotton fiber ball to clean the areas the pads volition become. There are also unmarried-employ cleaning wipes like the TENS Clean-Cote Skin Wipe that are specifically made for that purpose.
It not but cleans the area but it likewise prevents the oils from being captivated by the electrode gel.
To prevent the electrode pads from drying out, be sure to properly store them. Keep them in their packaging to lengthen their life.
You may also place them in the fridge to absurd them off after the TENS session. This cools them off to prevent them from easily drying out. A few drops of water placed on the pads before each utilise will also help hydrate it and set up it for possible heating while the treatment session.
How Long Do TENS Pads Last?
TENS pads tin normally concluding for upwards to five months with daily uses or nearly 150 uses. Properly caring and cleaning it will aid lengthen the average life span but they will need to exist replaced eventually.
Source: https://www.rootsofbeing.com/how-to-make-tens-unit-pads-sticky-again/